Since there are hundreds of millions of mobile phones in the world, to achieve safety, the failure rate of safety protection must be less than one in 100 million. Because the failure rate of circuit boards is generally much higher than one in 100 million. Therefore, when designing a battery system, there must be more than two safety lines of defense. A common wrong design is to use a charger (adaptor) to charge the battery pack directly. In this way, the responsibility of overcharging protection is completely handed over to the protection board on the battery pack. Although the failure rate of the protection board is not high, even if the failure rate is as low as one in a million, there is still a probability that explosion accidents will occur every day around the world. If the battery system can provide two safety protections for overcharging, over-discharging, and overcurrent, and the failure rate of each protection is one in ten thousand, the two protections can reduce the failure rate to one in 100 million.
Common battery charging systems include two major parts: a charger and a battery pack. ① The charger also includes two parts: an adapter and a charging controller. The adapter converts AC power into DC power, and the charging controller limits the maximum current and maximum voltage of DC power. ② The battery pack includes two major parts: a protection board and a battery cell, and a PTC to limit the maximum current. The role of the adapter AC to DC conversion: the controller limits the current and voltage. The role of the charger: the protection board protects against overcharge, over-discharge, overcurrent, etc.
The role of the battery pack: current limiting chip. Taking the mobile phone battery system as an example, the overcharge protection system uses the charger output voltage set at about 4.2V to achieve the first layer of protection. In this way, even if the protection board on the battery pack fails, the battery will not be overcharged and dangerous. The second protection is the overcharge protection function on the protection board, which is generally set to 4.3V. In this way, the protection board does not have to be responsible for cutting off the charging current at ordinary times, and only needs to act when the charger voltage is abnormally high. Overcurrent protection is the responsibility of the protection board and the current limiting chip, which are also two protections to prevent overcurrent and external short circuit. Since overdischarge only occurs during the use of electronic products. Therefore, the general design is that the circuit board of the electronic product provides the first protection, and the protection board on the battery pack provides the second protection. When the electronic product detects that the power supply voltage is lower than 3.0V, it should automatically shut down. If this function is not designed in the product, the protection board will close the discharge circuit when the voltage drops to 2.4V.
General: When designing the battery system, two electronic protections must be provided for overcharge, overdischarge, and overcurrent. If the battery explodes when charging after removing the protection board, it means that the design is poor. Although the above method provides two protections, consumers often buy non-original chargers to charge after the charger breaks down, and charger manufacturers often remove the charging controller to reduce costs based on cost considerations. As a result, bad money drives out good money, and many low-quality chargers appear on the market. This makes overcharge protection lose the first and most important line of defense. Overcharging is the most important factor causing battery explosions, so low-quality chargers can be regarded as the culprit of battery explosions. Of course, not all battery systems adopt the above solution. In some cases, there will also be a charging controller design in the battery pack.
The last line of defense: If all electronic protection measures fail, the last line of defense will be provided by the battery cell. The safety level of the battery cell can be roughly divided into levels according to whether the battery cell can pass external short circuit and overcharge. Because before the battery explodes, if there are lithium atoms accumulated on the surface of the material, the explosion will be more powerful. Moreover, the protection against overcharge is often only one line of defense because consumers use inferior chargers. Therefore, the battery cell's ability to resist overcharge is more important than its ability to resist external short circuit. Compared with the safety of aluminum shell battery cells and steel shell battery cells, aluminum shell has a higher safety advantage.